Load, grid and generator — tested to standard

From diesel gensets to grid-tied inverters and data-centre backup power — Langdi's intelligent load banks and test systems verify performance against GB/T 2820 and ISO 8528, in the factory or in the field.

The challenge

The grid keeps changing the rules

Inverters meet weak grids

Grid-tied PV and storage inverters must ride through low-impedance networks and disconnect on islanding — both need dedicated test platforms to prove.

Data centres can't blink

Backup gensets and UPS chains are only as good as their last commissioning test — high-voltage RC loads make the test real.

Standards demand documentation

ISO 8528 and GB/T 2820 acceptance testing needs controlled load steps and complete records, not clip-on meters.

What we test

Generation, storage and the loads between

  • Diesel & gas gensetsload acceptance, transient response and endurance per ISO 8528 / GB/T 2820.
  • Grid-tied invertersanti-islanding detection and weak-grid adaptive performance on precision RLC platforms.
  • UPS & backup chainsdata-centre commissioning with high-voltage resistive-capacitive loads.
  • Marine power systemspropulsion-load simulation and shore-power compatibility verification.
  • High-speed machinesturbomachinery and spindle motor stands from the motor bench family.
LOAD BANK TEST SYSTEM ISO 8528 · GB/T 2820 GENSET under test INVERTER PV · storage BUS · 400 V 3~ INTELLIGENT LOAD BANK R L C LOAD STEP 65% step · ramp · island · weak-grid profiles MEASUREMENT & CONTROL LDEV-X SCADA · LDRT
The Langdi stack for power & energy

SCADA-grade supervision, bench-grade data

LDEV-X SCADA model

Live single-line dashboards, load-step sequencing and alarm supervision — the same suite that runs our test benches runs your power lab. About LDEV-X →

LDRT — fast transients

Deterministic control captures load-acceptance transients that slow supervisory systems miss. About LDRT →

OPC UA · Modbus · S7

Open industrial connectivity integrates load banks with your plant, BMS or building systems.

Proven hardware

The intelligent load bank family

From the standard testbed catalogue:

StationaryHigh-power RLC dry-type · high-voltage RC for data centres · marine load banks.
Grid-compliance platformsAnti-islanding detection · weak-grid simulation for inverter validation.
Rack & portable19-inch rack 2U–6U (air- or liquid-cooled) · portable multi-unit-parallel · wall-mounted vehicle-integrated · mobile field units.
Test systemsComputer-controlled generator test per GB/T 2820 / ISO 8528 · production-line online generator test with one-click operation.
Next step

Commissioning, compliance or endurance?

Tell us the source, the standard and the site — we'll size the load and the measurement chain.

Talk to an Engineer